JCL & VSAM :: RE: TAPE VERIFY utility??

$
0
0
Author: enrico-sorichetti
Subject: Reply to: TAPE VERIFY utility??
Posted: Sat Dec 10, 2016 3:12 am (GMT 5.5)

BEWARE ... BEST EFFORT AT GUESSING

IIRC depending on the DFSORT configurations options
dfsort and friends can abend or issue a message with the same number as the abend

Quote:
For unsuccessful completion with ABEND in effect, DFSORT issues a user abend with the appropriate code as specified by the ABCODE installation option (either the error message number or a number between 1 and 99).


in this case - most probably - ICEGENER was substituted for IEBGENER
and the ICE0061A ( equivalent to the U0061 abend ) means that ..

Quote:
ICE061A
I/O ERROR, DD ddname, DEV address, ECB completion code, CSW status bytes, SENSE sense bytes
Explanation

Critical. This message was issued for one of the following reasons:
The job control statements incorrectly specified record length or blocking information for the data set located on the device indicated by the DEV field in the message.
A permanent error occurred during an I/O operation on the indicated device.
The most likely causes include:
The output data set of a merge, copy, or ICEGENER application is the same as one of the input data sets.
An output data set is the same as another output data set.
Hardware-related error.


_________________
cheers
enrico
When I tell somebody to RTFM or STFW I usually have the page open in another tab/window of my browser,
so that I am sure that the information requested can be reached with a very small effort icon_cool.gif